ÇѱÛÁ¦¸ñ(Korean Title) ¿øÀü ³» ¹«¼±Åë½Å Àû¿ë¿¡ ´ëÇÑ ÀüÀÚÆÄ ÀûÇÕ¼º Æò°¡¹æ¹ý ºÐ¼®
¿µ¹®Á¦¸ñ(English Title) Analysis on the EMC evaluating method for applying wireless communications in NPP
ÀúÀÚ(Author) °­½Â¼®   ÀÓÅÂÈï   ÁÖÀçÀ²   ±èÇüÅ   ±è´ëÈñ   º¯°­ÀÏ   ¹ÚÁ¾¾ð   ÀÌÁØ¿ë   ÃßÈ£¼º   SeungSeok Kang   Tae Heung Lim   Jaeyul Choo   HyungTae Kim   DaeHee Kim   Gangil Byun   Jong Eon Park   Jun-Yong-Lee   Hosung Choo  
¿ø¹®¼ö·Ïó(Citation) VOL 21 NO. 12 PP. 2221 ~ 2231 (2017. 12)
Çѱ۳»¿ë
(Korean Abstract)
º» ³í¹®¿¡¼­´Â ¿øÀü¿ë °èÃø¡¤Á¦¾î±â±â¸¦ Áø´ÜÇÏ°í À¯Áö¡¤º¸¼öÇϱâ À§ÇÑ ¹«¼±Åë½Å±â¼úÀÇ ±¹³»¿Ü Àû¿ë »ç·Ê, ÇÁ·ÎÅäÄÝ(Wi-Fi, Zigbee, Z-wave, WirelessHart µî) ¹× ±×¿¡ µû¸¥ ÀüÆÄƯ¼ºÀ» Á¶»çÇÏ¿´´Ù. ¶ÇÇÑ, ¿øÀü ³» ¹«¼±Åë½Å±â¼ú Àû¿ë½Ã ¿ì·ÁµÇ´Â ÀüÀÚÆÄ °£¼·(EMI/RFI)°ú °ü·ÃÇÏ¿© ±¹³» ±ÔÁ¦Áöħ KINS/RG-N03.09(°³Á¤ 2ÆÇ)¿¡¼­ ½ÂÀÎÇÑ RG.1.180(Regulatory Guide 1.180 rev.1), MIL-STD 461E, ¹× IEC 61000-4ÀÇ Â÷À̸¦ ºÐ¼®ÇÏ¿´´Ù. Ãß°¡ÀûÀ¸·Î ±âÁ¸ÀÇ EMC °ü·Ã ±ÔÁ¦¿¡ Æ÷ÇԵǾî ÀÖÁö ¾Ê¾Ò´ø, ½Ç³» ȯ°æ¿¡¼­ÀÇ ±¸Á¶Àû Ư¡, ÀüÆÄ»ê¶õ ¹× Â÷ÆóÈ¿°ú, ½Ç³» °¨¼â¸ðµ¨À» °í·ÁÇÑ ÀüÀÚÆÄ ¿µÇ⼺ Æò°¡¿ä¼Ò¿¡ ´ëÇؼ­µµ ¿¬±¸ÇÏ¿´´Ù.
¿µ¹®³»¿ë
(English Abstract)
In this paper, we surveyed previous cases, network protocols (such as Wi-Fi, Zigbee, Z-wave, and WirelessHart) and propagation characteristics on the application of maintaining equipments for instrumentation and control (I&C) using wireless communication techniques inside the nuclear power plant (NPP). In addition, we compared and analyzed the difference of detailed regulations with respect to the electromagnetic interference (EMI) and radio frequency interference (RFI) in the Regulatory Guide 1.180 rev. 1 (RG. 1.180) for adopting the wireless communication techniques inside the NPP, and other regulations, such as MIL-STD 461E and IEC 61000-4, that are recognized in the KINS/RG-N03.09 (Rev. 2). Furthermore, we investigated evaluating factors about electromagnetic properties by considering indoor environments, wave scattering, shielding effectiveness, and the indoor wave attenuation model that were not included in the current electromagnetic compatibility regulation.
Å°¿öµå(Keyword) ¿øÀڷ¹ßÀü¼Ò   °èÃøÁ¦¾î±â±â   ¹«¼±Åë½Å   ±¹Á¦Ç¥ÁØ   Nuclear power plant   Wireless communication   I&C equipment   Global standard  